MOCVD Susceptor
Reflector(Single crystal silicon
manufacturing equipment)
Pancake susceptor
Barrel susceptor
Name | Chemical formula | Concentration(%) | Temperature(℃) | Time(h) | Change in mass(g/m2) |
---|---|---|---|---|---|
Hydrofluoric acid | HF | 47 | 80 | 144 | -1.0 |
Hydrochloric acid | HCl | 36 | Boiling point | 144 | 0 |
Sulfuric acid | H2SO4 | 97 | 110 | 144 | 0 |
Nitric acid | HNO3 | 61 | Boiling point | 144 | 0 |
Hydrofluoric acid + nitric acid | HF+HNO3 (1:1) | 100 | 80 | 288 | -1.0 |
Nitric acid + sulfuric acid | HNO3+H2SO4 (1:1) | 100 | 25 | 288 | -1.0 |
Sodium hydroxide | NaOH | 20 | 80 | 288 | 0 |
Phosphoric acid | H3PO4 | 100 | 100 | 192 | -1.0 |
Nitrohydrochloric acid | HCl+HNO3 (3:1) | 100 | 80 | 192 | 0 |
Reactant | Chemical Formula | 1200℃×3h | 1600℃×3h |
---|---|---|---|
Aluminum | Al | ○ | △ |
Boron | B | ◎ | ◎ |
Cobalt | Co | △ | × |
Chromium | Cr | △ | × |
Copper | Cu | ○ | △ |
Iron | Fe | × | × |
Molybdenum | Mo | ◎ | ○ |
Nickel | Ni | ◎ | × |
Lead | Pb | △ | × |
Silicon | Si | ◎ | ○ |
Tin | Sn | ◎ | △ |
Tantalum | Ta | ◎ | ◎ |
Titanium | Ti | ◎ | ○ |
Vanadium | V | ◎ | × |
Tungsten | W | ◎ | ○ |
Alumina | Al2O3 | ◎ | × |
Boron oxide | B2O3 | ◎ | ◎ |
Chromium oxide (Ⅲ) | Cr2O3 | ◎ | × |
Iron oxide (Ⅲ) | Fe2O3 | × | × |
Magnesium oxide | MgO | ◎ | △ |
Manganese oxide (Ⅳ) | MnO2 | ◎ | × |
Lead oxide(Ⅱ) | PbO | ○ | △ |
Silicon oxide | SiO2 | ◎ | △ |
Titanium oxide (Ⅳ) | TiO2 | ◎ | ○ |
Vanadium oxide (Ⅴ) | V2O5 | ◎ | △ |
Zirconium oxide (Ⅳ) | ZrO2 | ◎ | ○ |
◎...No reaction ○...Slight reaction
△...Reaction ×...Significant reaction
Crystal structure |
β-SiC (Cubic system) Structure
|
---|---|
Bulk density | 3.2 Mg/m3 |
Decomposition Temperature | 2700℃ or higher |
Hardness | 2800HK |
Electrical Resistivity | 0.2 Ω・m (through the fall-of-potential method) |
Flexural Strength | 170 MPa (through 3-point bending) |
Young's Modulus | 320 GPa (through the deflection method) |
Element | Content |
---|---|
B | 0.15 |
Na | 0.02 |
Al | 0.01 |
Cr | < 0.1 |
Fe | 0.02 |
Ni | < 0.01 |
*Measurement method: Glow Discharge Mass Spectrometry
*The figures above are measurement examples and are not to be guaranteed.
Before actually using one of our products, please refer to our catalogue and be sure to contact our