Properties/Test Data
General Physical Properties
* The above numerical values are those taken from the below source and are not guaranteed values.
Source: H. Holleck: Material selection for hard coatings, J. Vac. Sci. Technol. A, Vol.4, No.6, Nov/Dec 1986
Reactivity with Various Substances
*◎:No reaction ×;Significant reaction
Hydrogen chloride reaction test: 20 Torr, HCl/H2 = 0.30/2.70 L/min (10%)
Ammonia reaction test: 20 Torr, NH3/H2 = 0.5/2.0 L/min (20%)
Hydrogen reaction test: 20 Torr, H2 3.0 L/min
Oxygen: Cracking and embrittlement of coating in low concentration oxidized atmosphere.
Impurity analysis example mass ppm
*1 < :Detection limit
*2 The figures above are measurement examples and are not to be guaranteed.